Models > 59670003000 > Instructions

59670003000 Kenmore Refrigerator - Instructions

All Instructions for the 59670003000
91 - 105 of 219
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
New Ice maker was install but technician failed to transfer arm off old ice maker and put on new one..
Work was done by service tech. I ordered the arm for my mom to save time when tech came back to do the job correctly.
Parts Used:
Ice Maker Shut-Off Arm
  • Royal from RICHMOND, VA
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers
2 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Water line feeding ice maker was not producing ice
Take out the elbow fill tube and check to see if ice build up inside tube. Clean tube of ice build up. Replace tube back in. In my case that corrected my problem.
Parts Used:
Plastic Tube Insert
  • Daniel from SAINT ALBANS, VT
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Pliers, Socket set
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
We thought the water valve was bad, but it wasn't The problem was the ice maker. We sent the valve back for a refund, and in addition there was no valve available that replaced the old one.
Took the ice maker out with three screws hving turned water off and unplugging fridge. Put a new one back in with the three screws. plugged fridge back in and turned water on. All done and everthing worked fine.

Ronald Stonis
Parts Used:
Water Inlet Valve
  • Ronald from CONCORD, NH
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
refrigerator stopped cooling due to condenser over-heating
Pull refrigerator out to access back, unplug unit and remove the 3 .25" screws cut the power leads to motor and install new with easy to understand instructions provided with new motor. Plug refrigerator back in and enjoy your cold beverages once more. EASIEST REPAIR EVER.
Parts Used:
Condenser Fan Motor Kit
  • Kevin from COVINGTON, LA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver, Pliers
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Fridge would warm above acceptable levels.
Talked to a bud who does this kind of work and he walked me thru the simple job. Also watched a you tube segment. Very easy job. Took off the front kick vent panel. Unscrewed the metal holder and unplugged old part, plugged new part in and put panel back on. Turned on unit and it is working like a charm. Got my fingers crossed just in case.
Parts Used:
Defrost Timer Kit - 120V 60Hz
  • Doug from BRANDON, MS
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Location of the run capacitor was not as the video described.
It was easy after it was apparent that the run capacitor was plugged into the compressor. This was determined from a parts diagram of the actual model refrigerator. The part was the same but the location on the video was wrong. A large screwdriver was used to unplug the capacitor from the compressor. The temperature range of the refrigerator is still too wide but it's colder.
Parts Used:
Run Capacitor
  • Robert from Webbers Falls, OK
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers, Socket set
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
My amana side to side freezer stoped freezing i found parts select and helped my get a part that by % would be the problemand it worked thanks
I replaced the run capacitor wich is located near the compressor, i first turned power off to fridge than remuved capacitor checked for continuity and the capacitor was the problem thanks
Parts Used:
Run Capacitor
  • Martin from SAN ANTONIO, TX
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Rocker on switch broke off
Eased the putty knife under the edge of the switch housing and pried it off. Pulled two wires off the old terminals and hooked them onto the new one and reinstalled into the refrigerator body.
Parts Used:
Refrigerator Door Switch
  • David Barnes from ROSWELL, NM
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    Less than 15 mins
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
light did not work on the refrigerator side
bulbs were not burnt out. received the new switch in a few days. watch the short video, was good to see how it comes out. used a putty knife to release the defective switch, removed wires put them on the new one and posed the new switch back in. Not bad Part cost $11.00 7 dollars shipping so for 17 bucks it works great. nice to see what is inside the refer!
Parts Used:
Refrigerator Door Switch
  • David from GROVESPRING, MO
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Motor noise while running and clicking when shutting off
The instruction sheet supplied with the new motor described the steps to take very good. Replaced the rubber grommets for the three motor mounts also. A flashlight or light source was needed or was very helpful.
Parts Used:
Condenser Fan Motor Kit
  • Curtis from Sedona, AZ
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Pliers
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Light switch broke off
We looked up the problem online with the model number of the refrigerator. We ordered the part and followed the video installation that was sent with the order and was found online prior to purchasing
Parts Used:
Refrigerator Door Switch
  • Kathy from TEMECULA, CA
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Pliers
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
noisy fridge, perimeter of door heating up
figured out the condenser fan was kaput. Tried WD, worked for several days then gave out completely. Took off back of fridge and trained small fan on compressor while I ordered new condenser fan. The swap was easy, undid the housing bolts, stripped off the connector, reconnected and voila! works perfect.
Parts Used:
Condenser Fan Motor Kit
  • craig from maple grove, MN
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Pliers
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Burned out socket, right side of refrigerator compartment.
I was changing a defective bulb and somehow the hot lead for the socket got grounded, and arched. This made the socket defective. I simply took out the defective socket and replaced it with the new one I ordered. Working fine now. PCH
Parts Used:
Light Socket
  • Philip from Chicopee, MA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Pliers
2 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Evap Fan Stopped Blowing..
My fridge / freezer started getting very warm. But, the compressor and condenser fan were operating. I chose the defrost timer from the parts select suggested list. I took it apart and noticed the contacts were in bad shape. I validated this with my dvm meter. By checking continuity across the contacts while turning the timer knob. I also used my meter to check for 115 vac across the 2, 1 connections. . As you turn the timer knob, you'll hear a click. This should close the contacts and connections 4,3 should power up the evap fan. I also pulled the evap fan and powered it up on my test bench. I did this just to validate the timer was the problem. So, if you have a running compressor and condenser fan. Check the contacts on the defrost timer located under the front grill of your unit with a dvm. There is a small gear motor that runs the timer. Don't be fooled by the fact it's running. If the contacts are toast, replace the timer unit. Total time to fix the problem should be 15 mins. Tops.
Parts Used:
Defrost Timer Kit - 120V 60Hz
  • James from Cave Creek, AZ
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver, Screw drivers
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
cooling fan quit
Ordered new fan motor on line took out old motor and replaced with new one
Parts Used:
Condenser Fan Motor Kit
  • George from Belhaven, NC
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the 59670003000