Fan had quit; needed replacement.
The fan was the correct part. It arrived one day after my well trained son-in-law had left for Texas. I had to install the motor myself. He had trained me well; it was not hard. the most difficult was getting the two tabs on the fan housing to fit back into the frame of the refrigerator where they belonged. Thanks. the part & delivery were overpriced, but I needed seed and convenience. Thanks for getting it right the first time.
John Moragues
Parts Used:
Condenser Fan Motor - 115V
  • John from Divide, CO
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers
10 of 15 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
noise from condenser fan
disconnect the power to the unit. remove the retainer sctrews on the mounting bracket. remove fan motor from unit. using the rerquired tools remove the fan from the old motor and install on the new one. torque the nut until all slack is out then 1/4 turn. reinstall motor assy. and reconnect power. test the system .
Parts Used:
Condenser Fan Motor - 115V
  • donald from opelousas, LA
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers
10 of 17 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Rubber actuator cover would not shutoff
Replaced the actuator rubber and back plate holder
Parts Used:
Actuator Pad Support Actuator Pad
  • James from Papillion, NE
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
11 of 21 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice maker would not shut off
Removed the ice maker from the freezer. Removed the switch. Tested the switch with a multimeter. Ordered a new switch. Replaced it in the box. Installed the ice maker ( 3screws and electric cord plug. It works. Details available on the internet.
Parts Used:
Icemaker Switch
  • Jack from Bloomington, IL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
8 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer not getting cold enough to freeze ice cream
I took the advice off of your website about the only thing that will fix
the problem is change the run capacitor. I felt assured that I would
have a working refrigerator freezer after making this change. I was
pretty disheartened when it didn`t solve anything. I was not going to
take the new part back out after the small challenge of putting it in.
The next day I found out how to test the old capacitor and it was still
good. I will just have to eat the $49. I did learn not to take advice from
a website even if it seems like a sure thing
Parts Used:
Run Capacitor
  • Gary from ROSETO, PA
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
6 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice trap door would not open
1. Unplug refrigerator or flip breaker to kill power to the refrigerator.
2. With hands, gently pull the bottom lip of the 3" X 11" face plate panel above the dispenser head.
3. Remove the 4 screws that are under the removed panel.
4. Tip the assemby down to reveal 2 plugs.
5. Gently pull the 2 plugs to disconnect.
6. Open the assembly to reveal the solenoid.
7. There are 3 screws at the base of the solenoid. The center screw attaches to the green ground wire.
8. Remove the three screws.
9. Observe: The bracket at the top of the solenoid unit tucks behind a 4th screw above the solenoid. You may need to loosen this screw to relesae the solenoid.
10.Unplug the yellow and red connector to the solenoid. It should not be totally free to remove.
11. Put the plunger into the solenoid. Note that the plunger has an opening to insert the white plastic trigger for the trap door. Make sure the trigger is inserted into this opening before reassembling.
12. Plug the yellow and red connector into the new solenoid.
13. Position the new solenoid to match the screw holes. The bracket at the top of the solenoid tucks under the 4th screw. Tighten as necessary.
14. Insert the green ground wire into the middle screw hole at the base of the solenoid and tighten.
15. Insert the two screws to either side of the ground wire and tighten.
16. Gently reconnect the two plugs.
17. Tip the assembly back into place making sure the trap door and hoses are lined up correctly.
18. Replace the 4 screws.
19. Snap the face plate back into place.
20. Turn on the power and give it a try!

I used other instructions provided by customers on the website. They were very useful.

This is the second time we replaced this unit. The first replacement failed within the one-year warranty period. I called customer service and they had a replacement part and refund for the previous part on its way immediately. Excellent service!
Parts Used:
Dispenser Door Solenoid Kit
  • Susan from Polson, MT
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
6 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator to warm
Instructions say run capacitor is by motor, but on this frige its in the refrigerator compartment. The capacitors looks different, one square and the other long
Parts Used:
Run Capacitor
  • Lloyd from PITTSBURG, CA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
5 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Unit had stopped making ice
Ordered the icemaker replacement. unplugged the unit, followed the simple instructions and got it done in less than 30 minutes. It did take a LONG time to start making ice. But it's working now.
Parts Used:
Ice Maker
  • Ron from ORANGE, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers
5 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The Ice Flapper warped and clogged up the Ice Shoot
I bought a Flapper replacement part from Parts Select. I installed it following their very complete on-line video directions. Their complete and easy to follow directions made my job very easy, and the work was completed without any problems and just as good as if it were done by a professional repair person. I am proud of my work, it couldn't have been done without their video insructions. Also I got delivery of the part within two days of my order. I will alway look for Parts Select any time I need an applicance repaired. Thanks to Parts Select!
Parts Used:
Dispenser Door Assembly or Flapper
  • Ronald from Elkridge, MD
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
5 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Drive cup broke due to ice cube jamming it
Remove three screws insert part; manually checked out drive and waited for ice to buildup and it worked like new.
Parts Used:
Ice Dispensing Drive Cup
  • Bruce from Mobile, AL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
5 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice chute frosted up
Procedure for Replacing the Ice Chute Plate
1. Turn off the power.
2. Snap off the outside trim ring. Use a plastic screwdriver to avoid scratching the cabinet.
3. Locate the three small holes below the control panel facing, just above ice chute. The center hole is not used. With a small, blunt, object (wire – blunted nail) that is slightly smaller than the holes, push up rather firmly up through the outer holes to release front control panel.
4. Remove the three wire connectors from printed circuit board. Firmly pull/pry them straight out of retaining clip. Use caution: Excessive force will break clips.
5. Release the secondary panel by removing four screws (one in each corner).
6. Remove the flap assembly.
7. Clean all accessible areas with 1/10 bleach water to sanitize. Rinse the cleaned area with clear water and thoroughly dry everything before re-assembling the panel.
8. Install the new flap assembly.
9. Re-installed everything in the reverse order and check the functionality.
10. Order a spare ice chute flapper to be ready for the next event.
Parts Used:
Dispenser Door Assembly or Flapper
  • Phillip from Springfield, VA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
6 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice Maker would not fill.
Was concerned that new icemaker was quite a bit different than the one we were replacing. Called GE to confirm it was correct.

Went ahead and installed the unit, using the supplied electric cable adapter.

A little difficult to deal with the extra cable, but everything worked OK and it's making ice normally.
Parts Used:
Ice Maker
  • Charles from Keller, TX
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
5 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
broken auger in the bucket assembly.
I ordered the wrong part, the ice maker assembly, because your diagram was not marked properly. I returned the part and you credited my account. Thanks. Ordered the new bucket. It worked fine. Now I have ice and crushed Ice whenever I want. Thanks.

p.s. I didnt use any tools, but to satisfy you I select nut driver.
Parts Used:
Ice Maker
  • Chip from Mandeville, LA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
6 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice Despenser wouldn't dispence ice
All i had to do was pop off the front trim, remove 4 small screws, unplug two plugs and replace the board.

It took me a grand total of 9 minutes to get the job done.

Way cheaper than having a repair man come to the house twice, once to diagnose, and once to replace the board he would have ordered and marked up.
Parts Used:
Dispenser Control Board - 2 Slide Switches
  • Blair from Evanston, WY
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
5 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
ice being made but would not dispense
Easy repair. Snapped cover off control panel. Removed 4 phillips head screws on control board assembly. Removed (2) connectors from assembly and pulled out defective unit. Installed new control board in reverse order. Everything now working. Very fast and easy repair once you have the part.
Parts Used:
Dispenser Control Board - 2 Slide Switches
  • Robert from Orlando, FL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
5 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!