No leveling feet on dryer.
This could not have been easier. The hardest part was tipping the dryer over on its' side.
Instructions:
1. Tip dryer over onto a non-scratch surface. I used a tarp on the floor.
Insert leveling foot into the foot opening on the bottom of the dryer &
screw in with fingers until it is difficult to turn.
2. Use the adjustable wrench on the hexed foot (not the threads) to adjust to the desired level.
3. Tip dryer upright taking care not to exert pressure on the feet closest to floor. I used a folded-up tarp under the bottom edge of the dryer while lifting it to the upright position.
4. Use a level, back to front & side to side, to determine if feet need further adjustment.
5. Adjustments can be made with the dryer in the upright position, using the adjustable wrench on the hexed foot.
Parts Used:
Leveling Foot
  • Bobbie from BEND, OR
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Wrench (Adjustable)
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Dryer was making noise - thought it was the belt, turned out to be the tensioner.
I followed the video provided by ‘Partselect’; although it was not the exact model it was close enough to get the job done with high confidence.
Parts Used:
Dryer Repair Kit
  • Steven from CAMARILLO, CA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Nutdriver, Screw drivers
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
My dryer made squeaking noise when rotating.
I followed directions found on several similar YouTube videos since the instructions included in the Whirlpool parts kit were not for my model dryer. I found that the original idler pulley was not rotating and the belt had worn a groove through it. I replaced all 4 roller wheels, idler pulley and the belt. Problem solved.
Parts Used:
Dryer Repair Kit
  • James from KENNESAW, GA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Nutdriver, Screw drivers
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
dryer was making a grinding noise
I researched causes of the noise, zeroed it down to the idler pulley. I then got the dryer schematic and took the dryer apart after disconnecting the power and the vent. i did not have to remove the drum, the idler pulley was easily accessible once the top and back panels were removed. I simply removed the drive belt from tension off the pulley, removed the old pulley and installed the new one. Once finished the dryer was running whisper quiet.
Parts Used:
Idler Pulley
  • Scott from MUNCIE, IN
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Dryer kept throwing the E1 error indicating the thermistor needed replacement
Unplugged the Dryer first. Removed the two screws from the bottom panel using a 1/4 socket and removed the panel by pulling down and out. Reached behind the blower and removed the connectors from the old thermistor and then the thermistor itself by removing the two 1/4 inch hex head screws. Replaced with new part and after screwing back in, reconnected the wires and replaced the panel. From start to finish, it took me about 20 minutes.
Parts Used:
Thermostat, Internal-Bias
  • Rory from LEESBURG, VA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Socket set
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The dryer would not heat up
I first tried replacing the Radiant Flame Sensor, which was located in a tight space and was very difficult to access. I finally gave up and called a handyman to replace it. That didn't fix my problem. I needed a new igniter. That was easy to replace, but it's fragile and I broke the first one...
Parts Used:
Igniter Kit
  • William from Canyon Country, CA
  • Difficulty Level:
    Difficult
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Screw drivers, Wrench set
3 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
No Heat from dyer
Well, this is quite easy really. I found the problem after plucking and chucking a few parts but it was finally the igniter that was the problem. After taking the front section panel off to access the components, take the time to unscrew the igniter and see if it is cracked. That is what happened to my unit. I replaced to the new M series coils as well but the issue was the igniter. Look very carefully for a crack, the one on my unit was very small. You can ohm it out with a meter and if it reads open it is cracked.
Parts Used:
M Series New Style Coil Kit
  • Jeff from Livermore, CA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers, Socket set, Wrench (Adjustable)
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Dryer would light for 30 secs. & flame would go out
Checked ignitor it was working ok, disconnected 3 pronged coil and disconnected 2 pronged coil using multi tester checked continuity on both coils both tested 0,with help of operator ordered M Series new style coil kit. When parts arrived installed coils attached wire harnesses installed bracket and 2 screws that secures coils. Started dryer it worked and stayed working who needs the Maytag Repair Man probably saved about 200.00 between service call and markup on coils. Thanks Virtual Repairman
Parts Used:
M Series New Style Coil Kit
  • Gary from Springfiled, OH
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
2 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
dryer not heating( after replacing the high temp. thermostat
i removed the door and front panel then removed the two screws holding the coil bracket,disconnected the two wires on coils,set new coils in place and reversed the above process
Parts Used:
M Series New Style Coil Kit M Series New Style Coil Kit
  • james from HURON, OH
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
2 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Dryer heats once when turned on and then you have to wait 15 minutes to restart it
Well, had I read more of the reviews on this website, I would have learned that my problem was the valve coils. Instead, I assumed it was the igniter, so I ordered and installed a new igniter to no avail. I was about to just go buy a new dryer at Home Depot and spend $600, but I had to try again so I read more reviews on this website and began measuring resistances across the valve coils and discovered I had a bad one. I ordered both just to be safe, and installed them and quickly enjoyed my first uninterrupted dryer cycle in over a year (for over a year, I had been stopping and restarting my dryer about 10 times for each cycle). So THANKS for this website and to all the home technicians who posted symptoms, resistances, and how-to-do-its to help me get this done. It was an empowering experience to fix this and have bookmarked this website for any future appliance fixes. It's a great website with all its schematics and postings.
Parts Used:
M Series New Style Coil Kit M Series New Style Coil Kit
  • Scott from Lake Forest, CA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers
2 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Gas dryer would not ignite.
I removed two wires from the coil valves. Then I removed two screws from the bracket that holds the coil valves in place. I removed the faulty coil valves and replaced them with the new ones. Put the bracket back on and replaced the two screws and wires. It took almost 5 minutes. The dryer is like new once again.
Parts Used:
M Series New Style Coil Kit
  • William from Plainfield, IN
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
igniter wold come on for a second then shut off no flame
removed the two screws that hold the coils in place pulled the coils terminal connections off removed and replaced with new coils reattached quick disconnect terminals dryer now works better than when it was new
Parts Used:
M Series New Style Coil Kit M Series New Style Coil Kit
  • shaun from mount laurel, NJ
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Socket set
2 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Dryer flame would light then would not ignite again
I used a socket to take of the front cover. I used a screwdriver to remove the two screws that held the coils in place. Replaced the coils and put everything backs together. Piece of cake!
Parts Used:
M Series New Style Coil Kit
  • Susan from Glendale, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers, Socket set
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The gas would not ignite.
First we removed the front panel then the door. Removed the old coils and put in the new coils, oh yeah don't forget to disconnect the power supply first. Sure enough that was all it took and it runs great. You really can fix your own appliance if you take the time to do some research.
Parts Used:
M Series New Style Coil Kit M Series New Style Coil Kit
  • Leslie from Idaho Falls, ID
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
2 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
no flame on burner after initial ignite
I shut off the power supply (pulled plug) . Opened the front access door on bottom of dryer, The two coils sat on top of burner unit, with a plate and 2 Phillip head screws securing them. .I used a small set of pliers to pull the terminals off, then I used a short Phillip head screw driver due to the proximity of the dryer drum close by. The coils slide off, slide the new ones on, re secure the plate with screws, reconnect the terminals, plug in the power cord and away you are for a fraction of the cost.
Parts Used:
M Series New Style Coil Kit M Series New Style Coil Kit
  • Thomas from Muskegon, MI
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Screw drivers
2 of 4 people found this instruction helpful.