Refrigerator was not cooling
This was a simple job. Raised the flap in the back that houses the compressor, removed the wire that holds the relay, pulled out the old relay and pushed the new one on. Replaced wire holder and that was it. Plugged it frig and freezer is at zero and lower compartment at 35. As easy as brushing your teeth!
Parts Used:
Run Capacitor
  • Vicki from Johnson City, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
16 of 23 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
I broke the fan while cleaning the coil
The broken fan made my refrigerator sound like a lawn mower I pulled the refrigerator out of it's nook and disconnected the power, removed the back panel with my battery powered drill motor, slid the old fan off of motor shaft, slid the new fan back on ran it to make sure the problem was corrected. The entire repair took less than fifteen minutes and was as simple as it could be. Please be careful when cleaning your coil, as the fan is easily damaged if you should contact it.
Parts Used:
Fan Blade
  • Raymond from Houston, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
13 of 15 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator quit running
I located the part that was the culprit as it had buzzed very much before quitting. This is an easy removal as the part is in a two prong jack and just needs to be carefully removed with the new part inserted back in the jack provided. The refrigerator works fine now, but the run capacitor will still buzz on start up of the compressor. I do hope this is normal in this model? anyway it runs fine mow. Thank you.
Parts Used:
Run Capacitor
  • Frederic from Daytona Beach, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
22 of 42 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Fan motor no longer functioning and needed to be replaced
The most difficult part was the removal of the existing fan and shroud. There is very little room to work between the condenser and the coils where the fan is located. The old shroud had to be removed as it was not compatible with the mounting for the new fan motor and blade. Make sure to unplug the refrigerator and give the coils some time to cool down. The first step was to remove the old fan blade... it simply pulls off. Next you need to remove the two bolts holding the fan shroud to the floor of the refrigerator. Then you need to remove the old fan motor from the shroud... unplug the wire connection and remove two small bolts that hold it on. I was lucky to have a VERY small ratchet to get into these tight spaces. Now is the really hard part, removing the metal fan shroud takes a lot of twisting and turning to get it out. The coils have a little play in them, but you must be very careful of the tubing and connections. Also, the coils are very sharp. Once this is out, IF you can get it out....I had my doubts along the way, you can start to put the new parts in... beginning with the new fan shroud which fortunately is made of plastic and has some give which makes it easier to get in. Then you can mount the new motor to the shroud with the three new screws. Plug in the wire connection, add the foam tape to the shroud and mount the shroud to the floor of the frig with the original two bolts. Lastly, attach the fan blade. This replacement kit is well constructed, fits perfectly and contained all the necessary parts (fan motor with wiring connection, mounting screws, wire connection adapter, fan shroud, foam tape and fan blade), but no detailed instructions come with it. I was lucky to get the old fan shroud out without doing any damage to the surrounding parts, but this part was very difficult for a do it yourself person. I would be interested to know if a professional has some other tips for this part of the replacement process.
Parts Used:
Refrigerator Condenser Fan Motor Kit
  • Amber from SHERMANS DALE, PA
  • Difficulty Level:
    Very Difficult
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Nutdriver, Pliers, Socket set
12 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Water was leaking from the filter area when in-door water dispenser used
Silly me. It couldn't possibly be the filter because it's worked for the last 9 months with no problems. Decided to replace the water filter base first. Repair was easy. I saw someone had trouble removing tubes from old base and I gave it a couple of tries to no avail so decided to cut the lines instead. Made it even easier. After repair, water continued to leak. So, replaced the filter itself and voila - leak fixed. Make sure you check the filter first. My mistake turned a $40 - 10 second repair into a $100 - 20 minute repair. Good Luck!
Parts Used:
Water Filter Base
  • Todd from Gotha, FL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers, Socket set
13 of 17 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
door was making a popping noise when you opened the door.
First I removed the door. Took off the broken parts and replaced them. Easy and fast to repair.
Parts Used:
Door Closing Cam Hinge Bearing Closer - Freezer Hinge Bearing
  • Judy from Visalia, CA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Screw drivers
11 of 11 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
when opening door you would hear a loud thump.
Removed stuff on door, removed 2 screws on top of door, lifted door off replaced one door closure/hinge bearing and one door closing plate and put door back on and wala no more thump.
Parts Used:
Door Closing Cam Hinge Bearing
  • James from Palm City, FL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers, Socket set
12 of 14 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The main Refidgerator door, made a cluncking sound
I removed the door by removing the top screw from the plastic cover, then slide it forward, then remove the two screws that hold the hinge on and then lifting the door off, once off the lower nylon hinge bearing comes right out of the door, the plate is removed with a screw driver. Installed in reverse order and cluncking was gone. 15 mins
Parts Used:
Hinge Bearing Hinge Bearing
  • Richard from Dunlap, TN
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver, Screw drivers
12 of 15 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Too of the rail supports inside the fridge were broken
First I removed two screws per rail and removed the old rails. I replaced with the new rails and used a nutdriver to secure in place. This was extremely easy and I fell like my fridge is brand new again.
You can do it!!!
Parts Used:
Meat Drawer Rail - Right Side Basket Hanger - Left Side
  • Kristen from Payson, UT
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
13 of 18 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
housing-crusher was broken
removed ice maker box and disassembled crusher unit on front of box and installed new housing.
Parts Used:
Dispenser Crusher Housing
  • Bob from Milton, WV
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
12 of 16 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Water leaking from back of refrigerator
Followed instructions from others on the blog. Shut off water and electricity to the refrigerator. Removed the cardboard plate. Removed the old water valve. Cut the compression valves off and inserted the tubes into the new water valve. Attached the water valve bracket to the fridge. Tightened copper water supply.Turned on the water - no leaks. Plugged the fridge in. Tried the water and ice in the door. No leaks - everything worked perfectly. THANK YOU PARTS SELECT!
Parts Used:
Refrigerator Water Inlet Valve
  • Barbara from Bryan, TX
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers, Wrench (Adjustable)
12 of 16 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Evavaporator making noises
Replaced an evaporator motor which had previouly been put in to replace original with an alternative which changed the original electrical connectors. Had to replace those replacements witn originals which extended the changeover.
Now works like the original and very quiet because your motor fit in the original rubber bushings. The alternative motor was put in by the Frigidaire repair man and at considerable expense because the warrenty date had been exceeded by one month.
Parts Used:
Evaporator Fan Motor Kit - 120V 60Hz Refrigerator Water Filter
  • Henry from Jupiter, FL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Pliers
12 of 16 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Support rail broke
I recieved the part within 48 hours. I snapped the part in place and I was done in seconds.
Parts Used:
Meat Drawer Rail - Right Side
  • Karl from Bellaire, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
10 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refridgerator freezing food
Unplugged fridge from outlet. Removed rear panel on freezer side. Removed defrost thermostat from tube and cut wires. Installed new thermostat by matching color coded wires and crimping with supplied connectors and snap back on tube. Reinstalled panel and shelving.
Parts Used:
Defrost Thermostat Kit
  • Bob from Gilbert, MN
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
18 of 34 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice make does not fill with water
I replaced the water valve, but it still did not fix the problem.The old water valve I took out I'm assuming worked fine, I think the real problem is ice building up in pipe or some other blockage.

Parts select was very fast in shipping, very positive experience with them.
I will definitely purchase again from this site.
Parts Used:
Refrigerator Water Inlet Valve
  • Amritpal from sacramento, CA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers, Socket set, Wrench set
12 of 16 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!