Fill cup broke.
Very easy to order from parts select. Took seconds to replace.
Parts Used:
Water Fill Cup and Bearing
  • Aliki from Miami, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
6 of 11 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
leaking ice maker,big chunks ot ice were forming and had to remove them 2-3 times a day
removed old ice maker by taking out a couple of screws in the back of freezer,when new ice maker arrived i saw that it didn't have the same hose apparatus as old one so I easily took apart old one then took apart new one and switched them out-very-- easily done for a 61 yr old lady I might add-- also had to reinstall ice maker arm off old ice maker as new one does not come with one Then installed new ice maker in freezer I am very very pleased,sure saved a lot of money doing it my self
Parts Used:
Replacement Ice Maker
  • Linda from Johnson City, NY
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
No ice cubes from ice cube maker
Happen to locate your site by Google. Was impressed and really pleased to find a schematic and directions to find and remove and specs to test the water valve and Defrost thermometer using an electric multimeter. You cannot tell by "looking" at a component if it is still OK.
So I put all the freezer contents into my beach cooler. The repair went as follows.
1. Removed the 6 screws from the back panel and pulled it out of the way.
2. Located the defrost thermostat and pulled it off of the coil.
3. Pulled the two connections off and took it to the bench to test. It showed no readings indicating it was dead.
4. Ordered a new one which came in two days.
5. Had to change the electrical connections using wire nuts.
6. Reversed the process plugged the refrigerator back into the wall. It started and later on I was getting ice cubes.
A great experience. Don't mess with repair guy as they normally are not up to speed on all devices and you are paying for them to learn how to repair your appliance in several trips. Probably using this site. If you can follow instructions, you can do this stuff.
Note. I tested the Water valve using given instructions. More time is used moving things around than the actual repairs. I avoided $150.00 for a new ice maker unit.
Parts Used:
Bimetal Defrost Thermostat
  • Walt from Van Nuys, CA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Nutdriver, Socket set
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Water overflowing ice maker
Removed the 3 screws that hold the ice maker in place and remove the cover and level wire. Put the cover and wire on new part and install the 3 screws. Had ice within 1 hour. A very easy job for the do it yourselfer. Suspect the heat coil that melts the cubes was not working in the old unit and cubes stayed in the tray.
Parts Used:
Replacement Ice Maker
  • James from Denver, NC
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
5 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice maker just stopped making ice
This was the third icemaker replaced since January 1999. Improvement need to be made in the design of the icemaker so that more than 2-3 years of life is available.
The most difficult part was disconnecting the power plug in the back of the icemaker. You must squeeze the upper and lower tabs together and pull out at the same time to disconnect. Once this is done, take out one nut head screw, lift up on the icemaker and remove from the hanger. Be careful that you don't break the plastic tabs on the hangers. Replace new icemaker in reverse, feed water supply where it must go in the back, resnap onto hangers, replace the nut head screw and snap in the power plug. It took about 2 hours before the icemaker began making ice. It has been working fine ever since. PS. I saved about $200.00 over having a repairman come in and replace the unit.
Parts Used:
Replacement Ice Maker
  • Thomas from Valencia, PA
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Nutdriver
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The refrigerator was warm/ freezer back frozen
Pretty simple really after reading online some other owners' experiences. This is a bottom freezer unit. Remove the ice maker, the tray slides, and the back cover of the freezer box. In my case I had to thaw it out with a hair dryer as the cover was frozen in place. I checked the old 'stat and found it was bad; I temporarily wired the leads together until the new 'stat arrived. It does allow the refrigerator to warm up during a defrost cycle but it beats de-icing it twice.The defrost 'stat is clipped over the refrigerant line in the upper right corner of the box. Resistance was 65k ohms and wouldn't close on low temp (tested by clipping it to an exposed refrigerant line in another upright freezer) but there was no obvious damage. The one lead on the replacement 'stat has the wrong connector so you have to cut off the original lead from the old unit and splice it on the wrong lead on the new one. I used an epoxy sealed heat shrink type butt splice. Reassemble and let it run. One word of warning: be careful tightening any screws as they will strip easily
Parts Used:
Bimetal Defrost Thermostat
  • David from Emmitsburg, MD
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
5 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
refrigerator was getting warmer.
first thing i thought was the condenser was plugged so pulled out and cleaned with shop vacum backwards so it became a blower not a vacum cleaned it good and put together. wife noticed cracking noise inside freezer. took all freezer food and shelfs out. took 1/4 inch hex nut screws out and found complete condenser solid ice. did some research on internet and found parts select stories. i buy passed thermostate and hooked heating coils direct which then thawed condenser. checked timer by turning of and it worked fine until i got part and installed.
Parts Used:
Bimetal Defrost Thermostat
  • david from bondurant, WY
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Fridge and Freezer getting too warm.
In Freezer, removed the 3 screws hold up the dial to select the temperature. Once this is lowered you see the Cold Control Thermostat. New one was a bit different, but still fit. I carefully bent the sensor wire to come around to the front of the so it would fit. Slide the plastic tube over the sensor wire. I guessed on the Red and Yellow wires. I don't know if it matters if this is AC. I think I had the Red closest to the front. 2 prongs for the ground, but just need the small one. Put is all back together and it is working great.
Parts Used:
Cold Control Thermostat
  • Ted from NEDERLAND, CO
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrig began to trip the GFI circuit in the garage. When plugged into a house interior circuit the lights and fan ran but no cooling in either the freezer or frig.
First of all I want to thank Michael from Carlisle,PA and this site for publishing Michael's info on the wiring specifics on the new 3 connector Start Relay ( WP2262185 ). The original relay only has 2 connectors The 2 orange wires which are combined to one female connector need to be clipped and separated each to its own connector. Refer to Michael's blog as to which wire goes to which connector on the Start Relay. I replaced the Run Capacitor, Start Relay and Overload just to be safe. The Start Relay was the actual culprit.Thank you for an excellent website!
Parts Used:
Run Capacitor
  • riley from CAVE CREEK, AZ
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Socket set
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The refrigerator stopped running
I was told to order the run capacitor and the technician thought it would repair the refrigerator; but it did not. The appliance technician had to take the run capacitor off and install what he called a "hard start" and the refrigerator is operating right now.
Parts Used:
Run Capacitor
  • Barbara H. from South Hill, VA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Screw drivers
4 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Circuit Breaker tripped/shut down frig. every 8 hrs when time switched on
Removed timer kit (this was the second time for this part)/ replaced - this is a fairly simple job and take 5 minutes. The defrost thermostat take about 10 minutes to get to and take out the old one, replacement is a 2 minute job, unplug and replace, the longest part of this job is getting the back of the freezer off and then replaced, but it is fairly simple to do. Total time to diagnose about 15 minutes, replacement parts arrived in 2 business days, replacement time 15 - 18 minutes total. Recommend getting the thermostat and timer together. The first time this happened, only order the timer but I think the problem was the thermostat all along and the time seemed to be operating but when it came on every eight hours it tripped the circuit breaker Not sure which was really the problem, but all working fine now.
Parts Used:
Defrost Timer Kit - 120V 60Hz Bimetal Defrost Thermostat
  • David from Atlantic Beach, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
ice maker was over filling and causing water to flow into ice dispenser and freezing it al together
First turned off the water and unplugged the refrigerator and then removed the old ice maker by first removing the side cover plate and then next removed the ice level detector. Remove the screws that hold the ice maker in place and rotating it somewhat soas to gain access to the wires and then unplugged them. Next I had to modify the way the water comes into the new icemaker by adapting a CPVC street ell to fit into the hole on the side and then hook up the water supply. Installation is just the reverse of removal.
Parts Used:
Replacement Ice Maker
  • Michael from Moore, OK
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice maker stopped working
After checking the water valves ordered new ice maker. received the part three days after ordering! Clearing out food, removing the old one and installing the new unit took under 15 minutes. Everything went fine.
Parts Used:
Replacement Ice Maker
  • Raymond from Panama City Beach, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver, Screw drivers
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Old Ice Maker failed
I removed the old ice maker and during the short disassembly noticed a burned out connection to the heater element that allows the ice to be broken free of the tray and dumped into the bin. Part Select had a new unit to me next day! I had watched their short install video, and read some of the user comments, already. Re-installing the new unit was a snap, and just as the video had described except for the mount bracket. The only thing that concerned me was that the new unit did not immediately do anything. I began to investigate and found that the flexible water "chute" connection had ice in it! I unplugged the refer, unscrewed the water filter and drained it. I disconnected the water feed on the outside back of the unit as well to make sure water could flow easily to the ice maker port. I filled the water filter with boiling hot water and replaced it, I plugged in the refer, and reprogrammed the date and time. Several hours later I checked the ice maker and it was -- making ice!
Parts Used:
Replacement Ice Maker
  • John from Gurnee, IL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice maker stopped functioning
Part received was what I needed. There was one issue--the 'feed' opening to receive water and direct it into the ice tray was a side feed and what I needed was a back feed. That means I had to do some exchanging of parts to make it work. That exercise took more time that the actual installation.
Parts Used:
Replacement Ice Maker
  • richard from colorado springs, CO
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Nutdriver, Screw drivers, Socket set
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!