No Heat sometimes, But for a moment then None
First and Foremost i was told that my problem was with the Thermal Fuse (Fix Ya.com), Then with the little Electrical knowledge I have thought Fuses don't turn on and off,If the fuse was bad i would get No Heat. (Even for a second) Fuses just don't turn on and turn off intermittently,when they go there done! So after a little research i decided to order the gas coil valve. I tilted the top up, two screws on the front panel, took that off and the valves were exposed,(bottom left) two screws too remove bracket then installed new coils on bracket,put back together and I Have Heat Again! NO problems what so ever since new install. I would say having not been for cleaning lint build up inside the machine (been 6 years) the Whole project took me Ten Minutes.
Parts Used:
M Series New Style Coil Kit
  • Scott from Sacramento, CA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver, Screw drivers
4 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
door would not latch
removed old latch with pliers - inserted new latch
Parts Used:
Door Catch
  • Paul from BENTONVILLE, AR
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Screw drivers
4 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Dryer was squealing
Disconnected Power cord, removed vent pipe, removed back panel, had to slide top cover off to remove additional screw holding back on. Went down to where the Idler Pulley was, removed old piece by depressing on the spring loaded actuator and slid it off the belt and all. Replaced same as removal.
Parts Used:
Idler Pulley
  • Kevin from VALDOSTA, GA
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers
4 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
1`) broken blower motor drive belt,2) blower moter drive belt pulley loosened & seperated from shaft
1) Unplugged unit & used the 5 in 1 tool to disengage top panel clips from top of front panel & tilted top panel up & out of the way, .
2) Disconnected electrical connection @ upper right of front panel, Used drill & 5/16" socket & adapter to remove 2 upper front panel screws on backside of panel & removed panel.
3) Removed 4 screws from lint screen duct, unplugged elect. con.@ the right & removed lint screen & duct from dryer bulkhead..
4) Loosened 2 top screws & removed 2 bottom screws from bulkhead & lifted bulkhead up & out & set aside.
5) Slid drum belt off the back of the drum & removed the drum
6) Ceaned the blower moter drive shaft threads & threads inside the shaft pulley. Used a file to clean up any burrs on shaft pulley, coated treads of pulley & shaft with red lock tite thread dressing & re-instaled pulley back onto shaft with ajustable pliers while holding blower fan blades steady from inside the blower motor housing. with other hand. note: (pulley is left handed thread)
7) Looped new belt onto drive motor pulley then worked it back onto blower moter pulley with one hand while turning the blades of the blower from inside the blower housing with other hand until it was back in place & ribs on belt were seated in the mating ribs of the pulley.
8) Put everything back in reverse order with the exception of removing the back panel to reinstall the drum belt onto the drive motor shaft pulley and tensioner @ bottom left in back of the dryer.

Hope this instructional is able to help some one else & good luck with your projects!
Parts Used:
Blower Belt
  • Tim from DUNCANVILLE, TX
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers, Socket set, Wrench (Adjustable)
4 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The dryer would not heat up
After opening the bottom access panel, I found a lot of lint build up which is very flammable. I took my leaf blower and cleaned it all out. Then I just followed the instructions that came with the part. But be careful as the igniter is fragile. I broke the first one...
Parts Used:
Igniter Kit
  • William from Canyon Country, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers, Wrench set
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Dryer heat would go off and timer would not move. Dryer would continuously run
Replaced coils on gas valve.
Parts Used:
M Series New Style Coil Kit
  • chuck from smithtown, NY
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
My drier would start create heat,than stop heating after 8-10minutes.
After reading the many different common stories,I replaced both coils (m series).Very simply lifted up the top of driver,held by 2 snap springs and 2 lint vent screws.Removed front cover,2 screws and 2 bottom snaps,coils down on bottom left.r/r both coils,reinstalled covers and let there be heat!This website is a blessing!!
Parts Used:
M Series New Style Coil Kit
  • Tom from Schaumburg, IL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Too much drying time, not hot enough
I removed the Drier Door and removed the Front Drier Panel exposing the Gas Valve & associated parts. I removed two (2) screws holding the Gas Valve Coils in place & replaced the 2 terminal coil, then replaced the screws, Front Cover & Drier Door. I liked the results so much, I ordered the other Gas Valve Coil and will replace it also when it arrives.

Good trouble shooting information.
Parts Used:
M Series New Style Coil Kit
  • John from Floyd, VA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Dryer would shut off mid way through cycle and give an E1 error code
After turning off the power to the dryer I removed two screws to the bottom front panel and droped it out of the way. I remved three screws hloding the lint screen in place just for better axcess to the element. I then removed the two wires attached to the element and then the two screws holding the element in place. I put everything back together in reverse. I also took the time to clean any dust and lint out.
Parts Used:
Thermostat, Internal-Bias
  • Dwayne from Bainbridge, PA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Socket set
5 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
ignitor failed to ignite gas or would fail to after first ignition.
Watched youtube video to problem shoot. Cause determined to be coils bad. Searched web found Parts Select to be easiest site to deal with and had coils for best price. Followed instructions supplied with parts. Dryer works like new.
Parts Used:
M Series New Style Coil Kit
  • CHUCK from HARDIN, KY
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
4 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Gas Dryer Runs With Heat for Less Than 5 minutes, Timer Won't Advance in Autodry
My gas dryer would run with heat for 5 minutes in all settings, but kick off and not heat again. Timer would not advance in autodry. Thought it was the cycling thermostat, so replaced that, but did not solve the issue. Ordered the coils, and cleaned out heavily clogged lint from bottom of lint trap, especially right above the fan motor at the bottom of the trap. Received the coils, opened the top and front, took out drum, and replaced the coils. The replacement took less than 2 minutes. Be careful putting the drum back on to make sure the felt is not caught inside the drum. You can give it a spin to make sure. Wear gloves, as I cut myself up pretty good on the edges of the dryer body. The inside of my dryer looks like a crime scene! Anyway, I put it back together, and it runs great. Solved the timer advance issue in autodry, and the heat kicks on and off when it is supposed to. Good luck! Thanks Part Select!
Parts Used:
M Series New Style Coil Kit
  • julia from WOODRIDGE, IL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers, Socket set
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Squeaky dryer
Ezee pezee lemon squeezee.
Parts Used:
Idler Pulley
  • robert from ELMA, WA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Squel with heavy load
Well before ordering parts. I removed back panel with screw gun to locate issue noise. The I applied a real quilty spray lube to the tensioner an spun it a few times. Then put dryer back together and ordered parts. I'm waiting for the noise to return before I actually make the repair. Old saying if it's not broke don't fix it.
Parts Used:
Idler Pulley Wheel and Arm Belt
  • Matt from SAINT LOUIS, MO
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
a portion of the felt seal was torn loose on the inside of the dryer and needed replacement
I spent the most time researching and confirming exactly what part I needed before ordering the shipment. The illustrations and videos available on how to replace the part(s) were VERY helpful and much appreciated.

I followed the instructions seen on video and removed the top and front of dryer. Then pre-fit the new seal - and stretched it out some while dry to make sure it fit the drum. Once fitted, then I glued 1/2 of it and let it stand for at least 30 minutes and then did the 2nd 1/2 after that. I sure needed clips to hold it in place before moving on to complete both halves. Then I tested it and it tested ok.

I have only noticed 1 spot where some adhesive ran out that shows but it was minor. Had to figure out how the main drive belt work with the pressure pully because it had come loose from the drum. Once past that - it just needed reassembly.
Parts Used:
Dryer Felt Seal
  • Keith from EAGAN, MN
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Nutdriver, Screw drivers
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Blower belt came loose, but didn't snap. It was old and perhaps brittle.
First, lift top by pushing in the 2 locking clips ( with the dryer door open), otherwise it won't lift.
Secondly, remove front cover by taking out 2 screws easily seen . If you see any electrical connectors, remove them.
Only thing a bit nightmarish was installing the new belt. It didn't seem long enough even though it was the original exact replacement. I got hair dryer blower, used on belt for 30 seconds, and mission accomplished.
Parts Used:
Blower Belt
  • Gabe from Tulsa, OK
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Nutdriver, Screw drivers
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?