Models > 59665934402 > Instructions

59665934402 Kenmore Refrigerator - Instructions

All Instructions for the 59665934402
106 - 120 of 726
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
lights wouldn't come on/work in refrigerator
Referencing the info/schematics you have on your website, I unscrewed/unattached top-front panel (carefully), from behind the panel you have to detach the wires (2) from the switch, pushed "in" the switch to remove, put in new switch and attach wires to test BEFORE remounting panel. Tada!! Thank you PartSelect! You saved me at least $80...would have been at least $100 to have a repair person come to the house!
Parts Used:
Refrigerator Door Switch
  • Jane from Albuquerque, NM
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Screw drivers, Socket set
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Raplaced switch
Repair went well,took about five to ten minutes to disconnect the power from the fridge removed the defective switch installed the new one ,reconnected the power,,,and Let there be light and there was light!
Parts Used:
Refrigerator Door Switch
  • Winston A from Brooklyn, NY
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Pliers
5 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer door handle was cracked
NEW SCREWS NOT INCLUDED with replacement handle! Removed old screws with a phillips screwdriver, cleaned them, reused screws to install new handle.
Parts Used:
Freezer Door Handle
  • EILEEN from TRUMANSBURG, NY
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Fill cup broke.
Very easy to order from parts select. Took seconds to replace.
Parts Used:
Water Fill Cup and Bearing
  • Aliki from Miami, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
6 of 11 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Water overflowing ice maker
Removed the 3 screws that hold the ice maker in place and remove the cover and level wire. Put the cover and wire on new part and install the 3 screws. Had ice within 1 hour. A very easy job for the do it yourselfer. Suspect the heat coil that melts the cubes was not working in the old unit and cubes stayed in the tray.
Parts Used:
Replacement Ice Maker
  • James from Denver, NC
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
5 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
leaking ice maker,big chunks ot ice were forming and had to remove them 2-3 times a day
removed old ice maker by taking out a couple of screws in the back of freezer,when new ice maker arrived i saw that it didn't have the same hose apparatus as old one so I easily took apart old one then took apart new one and switched them out-very-- easily done for a 61 yr old lady I might add-- also had to reinstall ice maker arm off old ice maker as new one does not come with one Then installed new ice maker in freezer I am very very pleased,sure saved a lot of money doing it my self
Parts Used:
Replacement Ice Maker
  • Linda from Johnson City, NY
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice maker just stopped making ice
This was the third icemaker replaced since January 1999. Improvement need to be made in the design of the icemaker so that more than 2-3 years of life is available.
The most difficult part was disconnecting the power plug in the back of the icemaker. You must squeeze the upper and lower tabs together and pull out at the same time to disconnect. Once this is done, take out one nut head screw, lift up on the icemaker and remove from the hanger. Be careful that you don't break the plastic tabs on the hangers. Replace new icemaker in reverse, feed water supply where it must go in the back, resnap onto hangers, replace the nut head screw and snap in the power plug. It took about 2 hours before the icemaker began making ice. It has been working fine ever since. PS. I saved about $200.00 over having a repairman come in and replace the unit.
Parts Used:
Replacement Ice Maker
  • Thomas from Valencia, PA
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Nutdriver
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
the rail to hold the crisper drawers broke
I first removed the bottom shelf. Then I popped the rail in. It was pretty easy although I did have to use some force to fit it in. Ordering the part and doing it myself was a lot cheaper than calling the repair man.
Parts Used:
Refrigerator Center Crisper Drawer Slide Rail - White
  • Christina from Orange, CT
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Center Crisper Rail Broke Off At One End--Drawers Would Not Slide And Hang Right.
Very easily removed top shel glass above crisper--removed old rail by lifting up--and place new one in slots provided---simple!! Part was delivered in less than 3 days-------very fast and cheap !!!
Parts Used:
Refrigerator Center Crisper Drawer Slide Rail - White
  • DANA from ASHTABULA, OH
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
4 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
broken roller
proped up frig, loosened screws, cut pin, installed rooler w/ new pin, rounded pin end, reistalled, lowered frig...everyone happy, thanks again partselect.
Parts Used:
Roller Pin Single Roller
  • John from Capac, MI
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
No ice
replaced inlet valve per insert with part, easy
Parts Used:
Water Inlet Valve - 120V 60Hz
  • LYNN from PANORA, IA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
4 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Fresh Food Compartment occasionally going down to 28-30 degrees F
Failure detected as Damper Control at upper rear of compartment would continuously open/close, would never stay open or closed. Sometimes the main board would turn it off (maybe a low thermistor limit?), but it would stick open a bit, and keeping letting freezer air into fridge. Could have potentially been control board, but as it turns out after disassembly of the defective damper, the internal microswitch was stuck in the closed position so it wouldn't shut off the motor. Easy fix by gently pulling the cover off the damper control, pull out Styrofoam encasement, then a phillips to remove the damper assembly. Gently push tabs to release wire connectors. Reverse the process and you're done! If I really wanted to go on the cheap, I could have just changed the microswitch, but that looked like a shaky maneuver at best. This site saved me on this one, so happy to share my experience with this Maytag and its nasty habit of freezing my milk and eggs!! :)
Parts Used:
Damper Control Assembly
  • Galen from WASECA, MN
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Center Crisper rail
Take everything off the top self, lift the self install the new part ,put self back in place and then install the drawers again. Took minutes.
Parts Used:
Refrigerator Center Crisper Drawer Slide Rail - White
  • Richard from PASADENA, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Broken center crisper rail
Total time 10 minutes. 9 minutes to clear out the food and 1 minute to install the part. Installation was self evident and could have been done blindfolded. Part just snapped in.
Parts Used:
Refrigerator Center Crisper Drawer Slide Rail - White
  • Allan from Tucson, AZ
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    Less than 15 mins
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Broken clips on old part
Snapped in new part
Parts Used:
Damper Cover Insert
  • Rose from OCOEE, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the 59665934402