Models > 25357682791 > Instructions

25357682791 Kenmore Refrigerator - Instructions

All Instructions for the 25357682791
106 - 120 of 418
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Freezer icing up and refrigerator section not cold
Removed four screws for cover on refrigerator temperature controls, unpluged old timer and pluged in new timer. Replaced cover and screws.
Parts Used:
Defrost Timer - 60Hz 120V
  • Les from Fenton, MO
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
the freezer was cold and the refrigerator was not! The eavaportor was icing up was not going thun the defrost cycle!
First I unplugged the appliance for safety,then I proceeded to remove the sheetmetal from inside, the freezer compartment, this is where the evaporator is located and where you will find the defrost limit switch or thermostat same thing. also the defrost heater is located here as well. I made note of what plugged into what and what the colors of the wires are for future use. You also need to check the defrost timer which on this unit, it is located in the very front lower left coner of the appliance. Once I received the parts I put things back together in the reverse order, plugged in the appliance and so far so good the refrigerator is cold now.There are a lot of repair manuels out there that will help you repair your appliances and save yourself a lot of money. You just have to be willing to do it yourself.
Parts Used:
Defrost Heater
  • gregory d from pensacola, FL
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Socket set
4 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
drawer slide was cracked
Took the front off my drawer and reinstalled it on the new drawer. Very easy.
Parts Used:
Water Filter Upper Crisper Drawer - Front NOT Included Water Filter Wrench
  • susan from palmdale, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrierator was getting warm
Changed the defrost timer and the Thermostat. Still did not fix the problem. Replaced the defrost heater and now it's cooling just like new.
Parts Used:
Defrost Heater
  • Mark from Statesville, NC
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers
4 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer frosted up, refrigerator compartment heated up
I removed the housing at the top of the refrigerator compartment that contained the reefer light and temperature adjustment knob. This required a small nut-driver. Inside, I found the old defrost control, unplugged it, unscrewed it with a Phillips screwdriver, and replaced it with the replacement part. Then I replaced the housing to its original position.
Parts Used:
Defrost Timer - 60Hz 120V
  • James from Hanover, ME
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer too cold
Removed the housing with the light, 4 hexhead screws. This exposed the defrost timer, removed 2 hexhead screws, electrical connector and reassembled the unit.

Great resource and service, thank you.
Parts Used:
Defrost Timer - 60Hz 120V
  • Curt from Maple Grove, MN
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer coils kept freezing over.
1. Turned off the cooling cycle and unplugged the refrigerator.
2. Removed all of the shelving and bottom basket.
3. Removed rear covering in the freezer section.
4. If frosted over, manually defrost coils with hairdryer.
5. Located original thermostat and after marking the wire locations cut the wires and removed the Thermostat.
6. Connected matching wires using a lighter to melt the wires together. Wrapped repaired wires with electricians tape.
7. Unable to install the thermostat in the recommended location (freezer is a tight fit) the new part was installed at the original location.
8. Replaced the rear cover and shelves.
9. Plugged in the refrigerator and set the cycle back to cooling.
10. Monitored freezer coils couple of days/weeks depending on how fast they freeze over (slots at bottom of cover) to validate if problem solved.
Parts Used:
Defrost Thermostat
  • Kyle from Porter, OK
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
4 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Rails broken on the upper storage drawer
The repair was extrememly easy and took about as long as it did to order the pasrt online. Just removed the front drawer handle with a screw driver ,slide it onto the new storage drawer and reinstall. Less than 5 minutes.
C.J.
Rochester Hills,MI
Parts Used:
Upper Crisper Drawer - Front NOT Included
  • Craig from Rochester Hills, MI
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator. Running all the time freezer cold but refrigerator part not cold.
I took everything out of the freezer. Removed All the shelves, took the front off of the evaporator coil compartment. Then I defrosted the evaporator coils with a blow dryer because they were basically a solid block of ice. Then removed the heater coil, installed a new one. Installed a new defrost thermostat. Put the evaporator coil panel back on. Then I turned the thermostat back up to where the fan came on and I noticed it took a few times for the compressor to continue to run. I don’t know what that was all about but eventually the compressor kicked in and everything worked like it should.
Parts Used:
Defrost Thermostat Defrost Heater
  • Reed from Cash, AR
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Nutdriver, Screw drivers
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice maker leaking, then would'nt shut off.
Ice maker is held by 2 screws just above the unit, on the wall of the refrigerator. You can't see the screws, so borrow your wife's makeup mirror. Shine a light into the refrigerator, and using the mirror, locate the two screws, holding the unit in place, on the wall of the refrigerator. Using a nut driver, or socket wrench, with a 1/4 in socket, loosen up the two screws, but don't remove them. Bump the unit upwards, and away from the screws. (BEFORE doing anything!! Shut off the water supply, unplug the refrigerator) When you get the unit freed up, just unplug the old unit, and install the new one. You don't even have to worry about the water lines, and you'll see why, when you get the old unit off. Just reverse the procedure, installing the new unit. Very Simple, 10 to 15 minutes tops.
Parts Used:
Replacement Ice Maker
  • Terry from KEYSTONE, IN
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
No water going to the ice maker
I replaced the water pressure valve, unplugged the power , turned the water off, took off the back cover, loosened the screws holding the valve on , disconnected the water lines, and replaced with the new valve and reassembled water lines and remounted valve, done.
Parts Used:
Dual Water Inlet Valve
  • Anson from OAKDALE, CT
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
sometimes it would go into defrost and would not go back to cooling.
I called the repairman who diagnosed the problem as a thermostat then had to order a thermostat took about 2 weeks to get back and install (cost little over $100). did good for about two weeks and same problem reoccured. I decided it was defrost timer and ordered from this site for $19.95 including shipping. I got on ( you tube ) and got instructions(recommend you tube) for DIY install about 15 to 20 minutes. Has been running great for about 3 weeks. ( YOU TUBE IS GREAT FOR A DIY REPAIR ON ABOUT ANYTHING)
Parts Used:
Defrost Timer - 60Hz 120V
  • Henry D from PETERSTOWN, WV
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
defrost heater not working; defrost timer not rotating so coils ice up
Checked for continuity in heater, defrost thermostat and defrost timer. Heater good; not sure about thermostat or timer. Replaced thermostat - no change. Replaced timer - rotating and heater working.
Parts Used:
Defrost Timer - 60Hz 120V
  • James from VOLANT, PA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Nutdriver, Screw drivers
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Stopped making ice.
Had to reach right hand to top of ice maker to locate hex head screws by feel, then place nut driver onto hex head by feel and then unloosen screws with lft hand ,a couple of turns, enough to lift ice maker off screws.
Replace new icemaker onto screws and tighten screws. The only problem incountered was the location and availability of having to feel with both hands to fit nut driver onto the screws.(could not see with my eyes because front of ice maker blocked view. )
Parts Used:
Replacement Ice Maker
  • WILLIAM from KERRVILLE, TX
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Evaporator In Freezer Freezing Up, Fridge Warm
Removed shelf brackets to allow the removal of the evaporator sheetmetal cover. Unpluged wires to thermostat ,removed defrost timer and plugged in new timer,(front left lower kick panel). Cut and resoldered wires to new thermostat reinstalled thermostat and cover in reverse order. I knew what parts I needed and how to repair the unit,however your customer comments were spot on and would help anyone perform a successful repair (you provide a helpful service for the public)
Parts Used:
Defrost Thermostat Defrost Timer - 60Hz 120V
  • DONALD from MECHANICSVILLE, MD
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the 25357682791