Sorry, we couldn't find any existing installation instruction that matched.
Replace failed fan in control box
After turning off the breaker to cut power to the oven, I opened the oven door and, using the PartSelect exploded diagram as a guide, I removed 3 screws from the underside of the control panel - I was then able to slide the panel up and out to remove it. Leaving all of the control wires (especially the ribbon) connected to control panel, I saw the fan assembly mounted to the rear of the control box.
I noted the position of the two attached wires - black on top (or left), white on bottom (or right). Using a nutdriver with an extension bar, I unscrewed 4 screws holding the assembly in place. I removed the old fan and installed the new fan in its place. It was necessary to bend the new fan's legs out a bit to get them to line up with the holes. I reconnected the wires as mentioned above, then reinstalled the control panel.
I tested the oven by turning the breaker back on and letting the oven heat up to 450 degrees. The fan turned on as expected. After the oven cooled off, I reinstalled the 3 screws to secure the control panel.
I noted the position of the two attached wires - black on top (or left), white on bottom (or right). Using a nutdriver with an extension bar, I unscrewed 4 screws holding the assembly in place. I removed the old fan and installed the new fan in its place. It was necessary to bend the new fan's legs out a bit to get them to line up with the holes. I reconnected the wires as mentioned above, then reinstalled the control panel.
I tested the oven by turning the breaker back on and letting the oven heat up to 450 degrees. The fan turned on as expected. After the oven cooled off, I reinstalled the 3 screws to secure the control panel.
Other Parts Used:
-
David from Richardson, TX
-
Difficulty Level:Really Easy
-
Total Repair Time:Less than 15 mins
-
Tools:Nutdriver, Socket set
30 of 33 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Lots of fan noise with f2 error code when oven on
Made triple sure electricity off. GE designed excellent access to box above oven. Remove three bolts above oven door on bottom of control panel. Slightly raise panel to take off control panel, let hang by wires. Fan in back wall behind panel and has two wires that unplug, four screws to remove. Plug in new fan, input 4 screws. Partselect excellent guide to make sure correct part was ordered, and very timely delivery. $85.00 part instead of $1500.00 new oven. Tip - Note that fan burns out when auto clean turned on. Stop doing that and problem doesn't repeat.
Other Parts Used:
-
lloyd from lorena, TX
-
Difficulty Level:Really Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Screw drivers, Socket set
6 of 6 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Oven over heat sensor in upper control compartment going off due to circulation fan failure.
Turn power to oven off at the breaker.
Remove access panel to upper control panel.
With the aid of an extension rod remove the hex headed screws succuring the fan to the baffle wall. Remove the fan. Replacement model did not have wire extending from it. So remove wire from original fan and attach it to the replacement fan terminals using an appropriate adapter. Install new fan in original position with original screws. Be sure to reconnect wire in the same orientation as the original fan (right side to white wire). Repeat process for the second fan in the upper control compartment. Handy trick for re-installing hex head screw in deep location....use a small piece of electrical tape to hold the hex head screw head inside the socket driver. After tightening is completed the tape will fall away from the screw.
Check that all wiring connections are back in place and tight. Re-install cover and turn the breaker back on. Test the oven out by heating it up again. It will take approximately 30 minutes to reach a steady state temperature inside the oven so that the circulation fans in the control panel turn on.
Remove access panel to upper control panel.
With the aid of an extension rod remove the hex headed screws succuring the fan to the baffle wall. Remove the fan. Replacement model did not have wire extending from it. So remove wire from original fan and attach it to the replacement fan terminals using an appropriate adapter. Install new fan in original position with original screws. Be sure to reconnect wire in the same orientation as the original fan (right side to white wire). Repeat process for the second fan in the upper control compartment. Handy trick for re-installing hex head screw in deep location....use a small piece of electrical tape to hold the hex head screw head inside the socket driver. After tightening is completed the tape will fall away from the screw.
Check that all wiring connections are back in place and tight. Re-install cover and turn the breaker back on. Test the oven out by heating it up again. It will take approximately 30 minutes to reach a steady state temperature inside the oven so that the circulation fans in the control panel turn on.
Other Parts Used:
-
Kurt from Novi, MI
-
Difficulty Level:A Bit Difficult
-
Total Repair Time:1- 2 hours
-
Tools:Wrench set
4 of 5 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
- < Prev
- 1
- Next >
Questions and Answers
We're sorry, but our Q&A experts are temporarily unavailable.
Please check back later if you still haven't found the answer you need.
- < Prev
- 1
- Next >
Sort by:
Search filter:
Clear Filter
Your search term must have 3 or more characters.
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Sorry, we couldn't find any existing answers that matched.Try using some different or simpler keywords, or submit your new question by using the "Ask a Question" button above!
Robert Lee
October 3, 2017
How do i replace the center cooling fan motor. It has a very bad squeal. I took off the center panel and i can see the fan. I need to know how to remove the fan and replace it. Thank you robert lee 951-532-3333
For model number JTP56ba2bb
Hi Robert,
Thank you for your inquiry. Just under the photo of the upper cooling fan motor with blade, you will find installation instructions from customers who have installed the parts themselves. I hope this helps. Thank you and have a great day!
1 person found this helpful.
Was this helpful?
Thank you for voting!
- < Prev
- 1
- Next >
Related Parts
Model Cross Reference
This part works with the following models:
PartSelect Number: PS237580
Manufacturer Part Number: WB26K5061
Manufacturer Part Number: WB26K5061
Brand
Model Number
Description