Product Description
Lower Spray Arm Base Specifications
This part fits just under the fine filter assembly and supports the lower spray arm.
How Buying OEM Parts Can Save You Time and Money
Part Videos
Replacing your General Electric Dishwasher Lower Spray Arm Base
Troubleshooting
This part fixes the following symptoms:
Not cleaning dishes properly | Not draining
This part works with the following products:
Dishwasher.
This part works with the following products:
General Electric, Hotpoint.
Part# WD12X10244 replaces these:
AP4300545, 1263951
Customer Reviews
Filter By Rating:
- < Prev
- 1
- Next >
Sort by:
Search filter:
Clear Filter
Your search term must have 3 or more characters.
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Sorry, we couldn't find any existing reviews that matched. Try using some different or simpler keywords.
Terry V - August 18, 2022
Verified Purchase
Tough repair
For a simple part to be replaced, we had to take a lot of the washer apart. With better forethought, it should’ve been able to be slipped in easier. The part itself, it’s very fragile. It can be broken easily. It should be me made of some metal material rather than plastic.
Bob G - February 20, 2020
Verified Purchase
all is great.
the part is great, the dishwasher ii working great. The best thing was that you folks had the part in stock. Thank you.
Ann F - January 31, 2020
Verified Purchase
Worked as expected
Arrived quickly. Perfect.
John C - March 11, 2019
Verified Purchase
Top notch part fast shipping a++++++++
Parts was a direct fit no issues could not ask for better A++++++
- < Prev
- 1
- Next >
Customer Repair Stories
Average Repair Rating: 1.6 / 5.0, 2 reviews.
What's this?
- < Prev
- 1
- Next >
Sort by:
Search filter:
Clear Filter
Your search term must have 3 or more characters.
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Sorry, we couldn't find any existing installation instruction that matched.
Telescopic sprayer assembly in the Spray Arm Weld broke top element popped out
First off on this model, if one of the telescopic spray arm weld assembly comes out it is NOT repairable you have to replace the whole part.
The assembly on my model number was simple you do NOT have to PRY anything out...(I broke the base spray arm trying to shove a screw driver into the Spray arm weld.(You could try this but chances are the plastic will break and I recommend replacing both parts why not???.)
There are two bolts on the sump protector basket that has to be removed first. They are 1/4 inch.
Once that cover is free there is a bolt (also 1/4 inch) on the base spray arm it is easy to see but hard to get to I used a very thin open ended wrench
1/3 turn at a time till I could get the socket on it.
Next there is a rubber gromet like thingy that just pulls loose remove it also.
Next take the spanner wrench (I used one with a rubber belt) wrap around base spray arm and turn counter clockwise it just unscrews.
reassembly is simple but this is GE so I inspected the sump and found one medal impeller and one black screw at the bottom!!!!!
The impeller is threaded and just screws onto the shaft (look at the diagrams on this web site to see placement.)
Throw the screw away it does nothing except if left there jacks up the impeller I am guessing it fell out of some factory workers pocket.
If after you put all the parts back in and the washer does not drain check your reassembly if you don't line the parts up just right the unit will not drain.
Don't forget the rubber grommet (not sure what it does but it's easy to replace after all is assembled) also there is a metal washer that is inbetween the base spray arm and the spray arm weld put it back before you click those two parts together it protect the plastic from wearing it is a bearing!!
If you found this site you are doing really good This site had all the diagrams I was looking for I love you guys you so rock!!! I wish the diagrams were bigger but they were adequate. GE 's site was no help and I doubt I will ever buy another one from them.
Good luck just remember look at the parts diagrams before attempting the repair.
The assembly on my model number was simple you do NOT have to PRY anything out...(I broke the base spray arm trying to shove a screw driver into the Spray arm weld.(You could try this but chances are the plastic will break and I recommend replacing both parts why not???.)
There are two bolts on the sump protector basket that has to be removed first. They are 1/4 inch.
Once that cover is free there is a bolt (also 1/4 inch) on the base spray arm it is easy to see but hard to get to I used a very thin open ended wrench
1/3 turn at a time till I could get the socket on it.
Next there is a rubber gromet like thingy that just pulls loose remove it also.
Next take the spanner wrench (I used one with a rubber belt) wrap around base spray arm and turn counter clockwise it just unscrews.
reassembly is simple but this is GE so I inspected the sump and found one medal impeller and one black screw at the bottom!!!!!
The impeller is threaded and just screws onto the shaft (look at the diagrams on this web site to see placement.)
Throw the screw away it does nothing except if left there jacks up the impeller I am guessing it fell out of some factory workers pocket.
If after you put all the parts back in and the washer does not drain check your reassembly if you don't line the parts up just right the unit will not drain.
Don't forget the rubber grommet (not sure what it does but it's easy to replace after all is assembled) also there is a metal washer that is inbetween the base spray arm and the spray arm weld put it back before you click those two parts together it protect the plastic from wearing it is a bearing!!
If you found this site you are doing really good This site had all the diagrams I was looking for I love you guys you so rock!!! I wish the diagrams were bigger but they were adequate. GE 's site was no help and I doubt I will ever buy another one from them.
Good luck just remember look at the parts diagrams before attempting the repair.
Other Parts Used:
-
Larry from Fort Worth, TX
-
Difficulty Level:A Bit Difficult
-
Total Repair Time:30 - 60 mins
-
Tools:Socket set, Wrench set
106 of 126 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
excessively delayed delivery
I couldn't do the repair because the parts arrived a week after I left, even though I paid extra for speedy delivery. And there was ZERO customer support - the phone message said they would not answer the phone, and the email response was a generic FAQ.
Other Parts Used:
-
Bonnie from KILLINGTON, VT
-
Difficulty Level:Very Difficult
-
Total Repair Time:More than 2 hours
5 of 5 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
- < Prev
- 1
- Next >
Questions and Answers
We're sorry, but our Q&A experts are temporarily unavailable.
Please check back later if you still haven't found the answer you need.
- < Prev
- 1
- Next >
Sort by:
Search filter:
Clear Filter
Your search term must have 3 or more characters.
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Sorry, we couldn't find any existing answers that matched.Try using some different or simpler keywords, or submit your new question by using the "Ask a Question" button above!
Megan
March 30, 2023
What should I do if I can't get the rubber connector to budge in order to replace this part?
For model number Gsd4060n20ss
Hello Megan, thank you for contacting us. We are providing you with a relevant video that will help you replace the lower spray arm base. We hope this helps, good luck with this repair!
2 people found this helpful.
Was this helpful?
Thank you for voting!
- < Prev
- 1
- Next >
Related Parts
Model Cross Reference
This part works with the following models:
PartSelect Number: PS1765974
Manufacturer Part Number: WD12X10244
Manufacturer Part Number: WD12X10244
Brand
Model Number
Description