Models
>
EI30BM55HSA
EI30BM55HSA Electrolux Microwave - Overview
Sections of the EI30BM55HSA
[Viewing 4 of 4]Manuals & Care Guides for EI30BM55HSA
Click to downloadInstall
Installation Instructions
(1.89MB)
Manual
Owner's Manuals
(9.11MB)
Specs
Product Specifications Sheet
(0.64MB)
Wiring
Wiring Diagram
(0.64MB)
Keep searches simple, eg. "belt" or "pump".
SWITCH
PartSelect #: PS8769124
Manufacturer #: 5304493153
The relay switch may also be known as the door micro switch and is a part for your microwave. The function of this part is to monitor the door latch and communicate whether the door latch is open or c...
$57.44
In Stock
Lower Handle End Cap - Stainless Steel
PartSelect #: PS2582956
Manufacturer #: 5304477330
$49.77
In Stock
Upper Handle End Cap - Stainless Steel
PartSelect #: PS2582977
Manufacturer #: 5304477353
$59.66
In Stock
Mounting Bracket
PartSelect #: PS2343044
Manufacturer #: 5304467709
Hardware sold separately.
$54.52
In Stock
Door Latch Spring
PartSelect #: PS979582
Manufacturer #: 5304440316
Sold individually.
$69.73
In Stock
Questions And Answers for EI30BM55HSA
We're sorry, but our Q&A experts are temporarily unavailable.
Please check back later if you still haven't found the answer you need.
- < Prev
- 1
- Next >
Sort by:
Search filter:
Clear Filter
Your search term must have 3 or more characters.
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Sorry, we couldn't find any existing answers that matched.Try using some different or simpler keywords, or submit your new question by using the "Ask a Question" button above!
Amy
April 4, 2024
microwave door has has a small piece of black plastic break off and a screw fall out down where door pivots. Now door is unstable and black gasket piece on inside will not stay in place. wondering what piece broke off and can it be replaced. We have been very pleased with performance of this over the stove microwave and really don't want to have to replace.
For model number EI30BM55HSA
Hi Amy, thank you for getting in touch. Based on the description, you may have a broken door stop, part number PS1993342. You may need to replace it to fix the issue. We hope this solves your problem!
1 person found this helpful.
Was this helpful?
Thank you for voting!
Related Parts:
- < Prev
- 1
- Next >
Common Symptoms of the EI30BM55HSA
[Viewing 3 of 3]No heat
Fixed by
these parts
these parts
Show All
Won’t turn on
Fixed by
these parts
these parts
Show All
Door not closing properly
Fixed by
these parts
these parts
Show All
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Timer would run but the microwave won't start
I first removed the top plate above the microwave door (3 screws), then I removed the plate containing the buttons and clock. The microwave has 3 relay switches and they are in a little holder. The holder was too difficult to remove so I just removed the bottom switch and replaced. The microwave started right up.
Parts Used:
-
Tim from Chicago, IL
-
Difficulty Level:Easy
-
Total Repair Time:30 - 60 mins
-
Tools:Screw drivers
87 of 138 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
microwave wouldn't turn on but timer worked.
was told buy a repair person to check the door micro switches as it was a common problem. removed the top plastic air grill to get access to the screw that holds in place the control cover. After unplugging the unit, i took out the (2) screws that held in the switches and removed them (3). One switch was a bit melted so i tested it with a 12 volt battery and it was bad. Ordered a new one from Part select and got it fast . Works great .
Parts Used:
-
Steve from Moorhead, MN
-
Difficulty Level:Easy
-
Total Repair Time:Less than 15 mins
-
Tools:Pliers, Screw drivers
35 of 56 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Microwave would count down but not run
After unplugging the unit remove the control face buy removing the screws. All three door switchs are on a bracket on the left. Remove the two screws holding the bracket in place and pull out. Disconnect the wires from the three switches and test each switch indivually to determine the bad one. I used a multimeter set on ohms.Replace the bad switch with the new one and replace all the wires. Reassemble the unit and you are good to go.
Parts Used:
-
Betty from Kimball, TN
-
Difficulty Level:Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Pliers, Screw drivers
29 of 48 people
found this instruction helpful.
Was this instruction helpful to you?